REP 6.2 Closer Encoder Sensor Replacement S48

PARTS LIST ON PL 5.19
Use this procedure to remove and install the Closer Motor Encoder
Sensor.
Removal Procedure
WARNING
Do not perform repair activities with the power on or electrical power
supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury. See Section 0, page vi for other languages.
1. Switch power OFF to eWire.
2. Disconnect the Power Cord.
3. Do REP 6.1
Closer Module Replacement
4. Locate the Encoder Sensor, near the disk encoder. Remove the M4
Screw to remove the Sensor Bracket.
5. Disconnect the Sensor Cable.
6. Remove the Sensor from the Sensor Bracket by removing the M3
screw.
GBC eWire
to remove the Closer.
01/26/2018
Installation Procedure
1. Attach the new Sensor to the Sensor Bracket using the M3 Screw.
Use the cutout in the bracket to align the sensor.
2. Secure the Sensor Bracket into place by tightening the M4 Screw.
Ensure that the Encoder is centered with the Sensor.
3. Connect the Sensor Cable
4. Do Rep 6.1
Closer Module Replacement
5. Connect the Power Cord.
6. Power ON the eWire.
4-131
to Install the Closer Module.