Installation Procedure
1. Place the new Tensioner Assembly onto the M4 studs and loosely
attach the M4 nuts. Ensure the Idler Pulley on the Tensioner
Assembly is lightly pressing the Timing Belt.
2. Adjust the Belt tension. The belt should be taut but still be able to flex
approximately 1" when you press on it.
3. Tighten the Tensioner mounting bolts when you have achieved
correct Belt tension.
4. Do REP 1.1
Top Cover Replacement
5. Connect the Power Cord.
6. Power ON the eWire.
GBC eWire
to install the Top Cover.
REP 2.13 Bypass Sensor Replacement, S1, S4, S5 & S16
PARTS LIST ON 5.2
Use this procedure to remove and install the Bypass Sensors (S1, S4, S5,
and S16)
Do not perform repair activities with the power on or electrical power
supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury. See Section 0, page vi for other languages.
1. Switch power OFF to eWire.
2. Disconnect the Power Cord.
3. Do REP 1.1
Top Cover Replacement
4. Locate the appropriate sensor on the Bypass Panel.
5. Disconnect the Sensor Connector at the Sensor.