3 PAPER TRANSPORT JAM CODES- J1xx and J2xx

RAP 3.1
J161- EXCESSIVE SKEW DETECTED
J161 is an optional jam code that can be turned on or off through the
service menu. When turned on, J161 will occur when the eWire detects a
sheet coming into the machine with more skew than eWire is capable of
correcting.
1. If J161 is occurring frequently, there could be misalignment between
the eWire and upstream device. Refer to Section 8 Installation and re-
check the alignment between eWire and the device feeding sheets to
eWire.
This clears the fault
Yes- Return to normal operation;
No- Go to step 2
2. If there are no problems with alignment between eWire and the
upstream device, check the upstream device to ensure that sheets
being fed from that device do not exceed the skew specifications of
eWire.
This clears the fault
Yes- Return to normal operation;
No- Go to step 3
3. Do GP 6.3.6 to access the Functional Tests Menu. From this menu,
Skew Jam can be turned on or off. If J161 is occurring when sheets
are not entering the eWire with excessive skew, turn Skew Jam
option off and evaluate the result.
This clears the fault
Yes- Return to normal operation;
No- Go to the RAP indicated by the new Jam Code.
GBC eWire
RAP 3.2
J244- UNBOUND BOOK PRESENT IN COLLECTION
TRAY
J244 occurs when a sheet or book is left over in the collection tray after it
should have fallen into the book drawer.
1. Go to Section 3 3.3 Sheets not Hooking and go through the
instructions there
This clears the fault
Yes- Return to normal operation;
No- Escalate to second level.
RAP 3.3
J260- NO LEAD EDGE AT SKEW SENSOR
DETECTED
J260 occurs when a sheet is detected at the entry sensor but not detected
by the skew sensor.
1. Perform GP 6.4.2 Sensor check of S6-S10
This clears the fault
Yes- Return to normal operation;
No- Go to step 2
2. Ensure that the eWire is properly aligned with the upstream punch.
Refer to Section 8, the installation manual for instructions.
This clears the fault
Yes- Return to normal operation;
No- Go to step 3
3. Perform RTP 3.5.2
This clears the fault
Yes- Return to normal operation;
No- Escalate to second level.