9. Disconnect the solenoid wires from the header. It may be necessary
to use long-nose pliers to reach the cable connection.
10. Loosen the M4 nuts (2) securing the Solenoid Mounting Bracket and
loosen the mounting bracket. Do not remove it completely.
GBC eWire
11. Using Pliers or a screwdriver, remove the e-rings securing the drag
finger link pin. Remove the link pin.
12. Use an adjustable wrench to loosen the nut connecting the solenoid
to the solenoid mounting bracket.
13. Remove the Solenoid from the module.
Installation Procedure
1. Reverse the steps from the Removal Procedure.
2. Do REP 4.1
Vacuum Stacker Module Replacement
Vacuum Stacker.
3. Connect the Power Cord
4. Turn on the eWire.