7. Do GP 6.3.7 Firmware Upgrade procedure to re-flash the Firmware
Re-flashing the firmware clears the fault.
Y
N
Go to Step 8.
Return to normal operation.
8. Do REP 9.2 Element drawer Interlock Switch Replacement to replace
the Interlock switch.
Replacing the switch clears the fault.
Y
N
Go to Step 9.
Return to normal operation.
9. Replace Interlock Switch Cable 7716714.
Replacing the cable clears the fault.
Y
N
Go to Step 10.
Return to normal operation.
10. Do REP 11.1 to replace the Main Control Board A.
Replacing the Main Board clears the fault.
Y
N
Escalate to second level.
Return to normal operation.
GBC eWire

g) Close Cover

This message is displayed when the Top Cover is left open or not
properly closed.
1. Open the Top cover and close it firmly
This clears the fault
Y
N
Go to Step 2.
Return to normal operation
2. Insert an Interlock Cheater into the Top cover interlock Switch.
Moving Parts, keep hands clear of nips and the belts when
the Interlock Cheater is inserted. See Section 0, page vii
for other languages.
3. Check if the Close Cover message is displayed.
The Close Cover message is displayed
N
Y
Do ADJ 1.7 Top Cover interlock switch adjustment.
Go to Step 4.
4. Do REP 1.5 to remove the Rear Cover and check if the Interlock
cable 7716716 is connected at J16 at the "A" Main control board.
Interlock cable is connected at J16
Y
N
Go to Step 5
5. Switch OFF machine and unplug power cord.
6. Remove the M4 screws that hold the Interlock Switch Bracket (PL
5.25) and inspect the connections at the Interlock Switch (see
REP 9.2 Interlock switch replacement for photos of the connections).
Interlock cable is connected at the Interlock switch.
Y
N
Make the connection and return to Normal operation
Go to step 7.
01-26-2018
2-8