Installation Procedure
1. Install the new Interlock by pressing it into the Interlock Bracket until
the tabs snap into place.
2. Reattach the wires, being careful to maintain the correct wire
orientation.
3. Position the Interlock Bracket on the Frame and secure it using the
M4 Screws (2).
4. Do ADJ 1.7 to adjust the Interlock Flag position on the Element
Feeder Door and/or Book Tray Door.
5. Connect the Power Cord
6. Turn power ON to eWire.
Repairs/Adjustments

REP 9.3 Upper Bypass Latch Replacement

PARTS LIST ON PL 5.27
Use this procedure to remove and install the Upper Bypass Latch. Refer
to REP
2.27
Upper Bypass Latch Replacement to replace the male
portion of the latch.
WARNING
Do not perform repair activities with the power on or electrical power
supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury. See Section 0, page vi for other languages.
1. Switch power OFF to eWire.
2. Disconnect the Power Cord.
3. Remove the M3 Screws (4) from the Latch Housing, and remove the
old latch.