5. Visually check if the rollers of the Holder are centered in the cam
tracks.
The rollers are centered in the cam tracks
Yes- Go to Step 6
No- Escalate to a Specialist
6. Check if the set screws on all the six pulleys associated with the
Holder linear drive are tight
The set screws are tight
Yes- Go to Step 7
No- Tighten the loose set screw(s) and resume operation
7. Manually move the Holder linear mechanism and watch if the sheet
metal feature blocks/unblocks S37 Holder Stack position sensor.
The sensor is blocked/unblocked properly
Yes- Go to Step 8;
No- Escalate to second level
GBC eWire
8. Do GP 6.5 to check M15 Holder linear drive motor
This clears the fault
Yes- Return to normal operation;
No- Go to step 9
9. Inspect the springs for the Holder gates (PL 5.21).
Holder gates springs are present and not damaged
Yes- Go to Step 10;
No- Replace the missing/damages spring
10. Do 6.3.6 FIRMWARE UPGRADE Procedure to Re-flash the firmware
for eWire.
This clears the fault
Yes- Return to normal operation;
No- Go to Step 11
11. Do ARP 11.3 "B" Main Control Board Replacement.
This clears the fault
Yes- Resume operation;
No- Escalate to second level