REP 5.4 Sensor Replacement, Bind Deflect S3

PARTS LIST ON PL 5.16
Use this procedure to remove and install Deflector Bind Deflect Sensor
WARNING
Do not perform repair activities with the power on or electrical power
supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury. See Section 0, page vi for other languages.
Removal Procedure
1. Switch power OFF to eWire.
2. Disconnect the Power Cord.
3. Do REP 5.1
Deflector Module Replacement
Module.
4. Locate the Bind Deflect Sensor S3. The sensor is located in a cutout
near the center of the Deflector Frame.
5. Disconnect the Sensor Cable.
6. Remove the Sensor Bracket by loosening the M3 Screws (2)
7. Remove the old Sensor by removing the M3 mounting screw.
Repairs/Adjustments
to remove the Deflector
Installation Procedure
1. Install the new Sensor into the Sensor Bracket. Use the cutout to
align the sensor.
2. Attach the Sensor Bracket to the Deflector.
3. Connect the Sensor Cable to the new Sensor.
4. Do REP 5.1
Deflector Module Replacement
Module.
5. Connect the Power Cord.
6. Power ON the eWire.
7. Do GP 6.3.2 to verify sensor function.
01/26/2018