Rep 2.8 Bypass Timing Belt #1 Replacement - GBC eWire Service Manual

Table of Contents

Advertisement

REP 2.8 Bypass Timing Belt #1 Replacement

There are two timing belts used at the rear of the eWire Upper Bypass
Assembly. The procedure below can be used for the upstream (paper
entry side) Belt.
Type of Belt
Location
Belt, 502T, 2MM 2GT
Upstream
Belt, 555T, 2MM 2GT
Downstream
Removal Procedure
1. Turn power OFF to the eWire.
2. Remove the Power Cord.
3. Do REP 1.1
Top Cover Replacement
4. Do REP 2.18
Solenoid Replacement, Diverter Solenoid (L1)
remove the Diverter Solenoid
5. Remove the Rear Electrical Cover by removing the M4 Screws (5).
Repairs/Adjustments
Motor
M1
M2
to remove the Top Cover.
to
6. Relieve tension on the Belt by loosening the M4 screws (2) on the
Belt Tensioner.
7. Disconnect the cables running through the cable control bracket by
disconnecting it at the header.
8. Remove the wire control bracket from the frame by loosening the M4
Screws (3).
9. Carefully remove the Belt by lifting it off of the Idler Pulleys and Drive
Pulleys and remove the old belt.