5. Inspect the Element belt (PL 5.8.) Check for missing teeth or any
other damages
Element belt is in good condition
Yes- Go to Step 6
No- Replace the Element belt (REP 3.6)
6. Do GP 6.4 to check S25 Element belt home sensor
This clears the fault
Yes- Return to normal operation;
No- Go to step 7
7. Do ADJ 1.6 Element feed belt tension adjustment
This clears the fault
Yes- Return to normal operation;
No- Go to Step 8
8. Inspect Element feed belt idler for any damages or signs of wear (PL
5.9)
Element feed belt idler is in good condition
Yes- Go to Step 9;
No- Replace Element feed belt idler (REP 3.11)
9. Inspect Element belt idlers (2x) (PL 5.9)
Element belt idlers are in good condition
Yes- Go to Step 10;
No- Replace Element belt idler (REP 3.11)
10. Do GP 6.5 to check M10 Element feed belt motor
This clears the fault
Yes- Return to normal operation;
No- Go to step 11
11. Do GP 6.3.7 FIRMWARE UPGRADE Procedure to Re-flash the
firmware for eWire.
This clears the fault
Yes- Return to normal operation;
GBC eWire
No- Go to Step 12
12. Replace the Element feed belt (REP 3.6)
This clears the fault
Yes- Return to normal operation;
No- Go to Step 13
13. Do REP 11.3 "B" Main Control Board Replacement.
This clears the fault
Yes- Return to normal operation;
No- Escalate to second level