Rep 8.18 Holder Link Replacement - GBC eWire Service Manual

Table of Contents

Advertisement

REP 8.18 Holder Link Replacement

PARTS LIST ON PL 5.21
Use this procedure to replace the Holder Link.
Removal Procedure
WARNING
Do not perform repair activities with the power on or electrical power
supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury. See Section 0, page vi for other languages.
10. Switch power OFF to eWire.
11. Disconnect the Power Cord.
12. Open the Lid and Lower Bypass.
13. Remove the M3 Nylock Hex Nut and washer securing the Holder Link
to the Holder Rotate Mandrel to release one end of the link.
14. Remove the M4 Hex Nut, Screw and Spacer securing the Holder Link
to the Front Element Holder Hinge. Hold the top of the screw head
with an Allen wrench or a finger when loosening the nut to prevent the
screw and spacer from falling into the machine.
Repairs/Adjustments
15. Remove the old Holder link from the machine and install the M4
Screw and Spacer into the new Holder link as shown.
01/26/2018