Dfa Status Procedure - GBC eWire Service Manual

Table of Contents

Advertisement

4. Press the down arrow to scroll through the available Sensors until you
locate the Sensor you wish to test.
5. Locate the Sensor on the machine. Refer to
locating a specific Sensor.
6. Verify that the Sensor reads "0" when unblocked and "1" when
blocked. You can do this by manually covering the sensor with a
piece of paper or other object.
7. If the Sensor does not behave as expected, refer to the
troubleshooting steps in
GP 6.4
Sensor.
8. When you have completed the Sensor check, scroll down to
PREVIOUS MENU or EXIT to leave Sensor mode.
9. Select EXIT and press ENTER to return to the top level menu.
General Procedures and Information
GP 6.4
for help in
Sensor Checks to troubleshoot the
GP 6.3.3

DFA STATUS Procedure

The DFA Status procedure allows you to view the status of the
communication signals.
Procedure
Do the following to check the signals
Enter Service Mode by following the procedure described in
Scroll down so the return symbol is next to the words DFA STATUS.
Press ENTER to enter DFA Status mode.
SENSORS
DFA STATUS.
Press the down arrow to scroll through the DFA STATUS values.
C6=0 C7=0
S0=0 S1=0 S2=0
Select EXIT and press ENTER to return to the Service Mode Menu.
01/26/2018
6-12
GP 6.1.3
*
*