Installation Procedure
1. Attach the new Motor to the Holder Rotate Assembly using the
#4-40 Screws (4).
2. Tighten the set screw to secure the Rotate Shaft to the Motor
Shaft.
3. Position the Holder Rotate Assembly within the Holder.
4. Attach the Crank Block to the Holder Rotate Shaft using the M4
Screw and Spacer.
5. Secure the Holder Rotate Assembly to the Holder frame using the
M4 Screws (4).
6. Attach the Sensor Cables.
7. Connect the Motor Cable.
8. Connect the Power Cord and resume operation.
GBC eWire

REP 8.10 Closer Linear Drive Belt Replacement

PARTS LIST ON PL 5.21
Use this procedure to remove and install the Closer Linear Drive Belt.
Removal Procedure
Do not perform repair activities with the power on or electrical power
supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury. See Section 0, page vi for other languages.
1. Switch power OFF to eWire.
2. Disconnect the Power Cord.
3. Open the Lid and Lower Bypass.
4. Loosen the M4 Screws (2) securing the Timing Belt Bracket and
adjust the Bracket to relieve tension on the Belt.