Rep 8.3 Holder Position Near Element Sensor S40 - GBC eWire Service Manual

Table of Contents

Advertisement

Installation Procedure
1. Install the new Sensor by tightening the M3 Screw. Use tabs for
alignment.
2. Connect the Sensor Cable.
3. Close the Lid
4. Connect the Power Cable
5. Turn power ON to the eWire.

REP 8.3 Holder Position near Element Sensor S40

PARTS LIST ON PL 5.20
GBC eWire
Use this procedure to remove and replace the Holder Position Near
Element Sensor, S40
Removal Procedure
Do not perform repair activities with the power on or electrical power
supplied to the machine. Some machine components contain
dangerous electrical voltages that can result in electrical shock and
possible serious injury. See Section 0, page vi for other languages.
1. Turn off Power to the eWire.
2. Disconnect the Power Cord.
3. Raise the Lid and Lower Bypass.
4. Locate the Holder Position Near Element Sensor, at the forward edge
of the Holder module, near the Deflector and Element Feeder. Refer
to PL 5.20 and GP 6.4.3.
5. Disconnect the Sensor Cable.
6. Remove the Sensor by removing the M3 Screw.