Figure 3 Circuit diagram
Status Indicator RAPs
05-300, 05-305
05-305 DADH Top Cover Open RAP
05-305 The DADH top cover interlock switch detects that the top cover is open.
Initial Actions
•
Remove all documents from the DADH.
•
Check the top cover interlock actuator, Figure 1. If the actuator is damaged, install a new
DADH top cover, PL 5.20 Item 15.
•
Make sure the latch springs, PL 5.20 Item 7 are installed correctly. Make sure that the top
cover closes correctly. If necessary, install a new top access cover assembly, PL 5.20
Item 17.
Procedure
Switch off the electricity to the machine, GP 14. Disconnect the power cord from the
customer supply while performing tasks that do not need electricity. Electricity can
cause death or injury. Moving parts can cause injury.
Enter dC330 code 05-305 to check the DADH top cover interlock switch, S05-305. Activate
S05-305. The display changes.
Y
N
Go to Flag 1. Check S05-305.
References:
•
GP 13 How to Check a Switch.
•
P/J187, DADH PWB.
•
01G +24V Distribution RAP.
•
The 24V return in the 01B 0V Distribution RAP.
Install new components as necessary:
•
DADH top cover interlock switch, PL 5.15 Item 11.
•
DADH PWB, PL 5.10 Item 5.
Check that S05-305 is installed correctly. Install new components as necessary.
August 2007
2-110
WARNING
WorkCentre 5687 Family