077-308 Left Hand HIGH Interlock Open RAP

BSD-ON:1.4
The L/H-H Cover is open.
Initial Actions
Power OFF/ON
Opening/closing of the IOT L/H-H Cover.
Procedure
Check opening/closing of the IOT L/H-H Cover. The IOT L/H-H Cover can be opened/
closed.
Y
N
Reinstall the IOT L/H-H Cover.
Check the installation of the Exit 2 Interlock Switch. The Exit 2 Interlock Switch is installed
correctly.
Y
N
Install the Exit 2 Interlock Switch correctly.
Execute
Component Control
[071-304 Exit 2 Interlock Switch]. Open/close the IOT L/H-H
Cover. The display changes.
Y
N
Check the connections of P/J434, P/J116, P606,
P606,
J606
and
SJ1
are connected correctly.
Y
N
Connect P/J434, P/J116, P606,
Check the wire between J434 and J116 for an open circuit or a short circuit (BSD 1.4
7/Flag
8). The wire between J434 and J116 is conducting without an open circuit or
a short circuit.
Y
N
Repair the open circuit or short circuit.
Check the conductivity of the Exit 2 Interlock Switch
13 (BSD 1.4
Flag 7/Flag
8). The wire between J434-12 and J434-13 is connecting
successfully when the IOT L/H-H Cover is closed, and is insulated when the cover
is open.
Y
N
Replace the Exit 2 Interlock Switch
Replace the MCU PWB
(PL
9.1).
Replace the MCU PWB
(PL
9.1).
Launch Version
WorkCentre 5225, 5230
J606
and SJ1. The P/J434, P/J116,
J606
and SJ1.
(PL
6.4) between J434-12 and J434-
(PL
6.4).

077-309 Left Hand Low Interlock Open RAP

BSD-ON:1.4
The L/H Lower Cover is open.
Initial Actions
Power OFF/ON
Opening/closing the L/H Lower Cover.
Procedure
Check opening/closing of the L/H Lower Cover. The L/H Lower Cover can be opened/
closed.
Y
N
Reinstall the L/H Lower Cover
Check the installation of the L/H Lower Cover Interlock Switch. The L/H Lower Cover Inter-
lock Switch is installed correctly.
Y
N
Install the L/H Lower Cover Interlock Switch
Execute
Component Control
[071-302 L/H Lower Cover Interlock Switch]. Open/close the L/H
Lower Cover. The display changes.
Y
N
Check the connections of
rectly.
Y
N
Connect
P/J106
and P/J410.
Flag
Check the wire between J106 and J410 for an open circuit or a short circuit (BSD 1.4
1/Flag
2). The wire between J106 and J410 is conducting without an open circuit or
a short circuit.
Y
N
Repair the open circuit or short circuit.
Check the conductivity of the L/H Lower Cover Interlock Switch
and J410-12 (BSD 1.4
Flag 1/Flag
necting successfully when the L/H Lower Cover is closed, and is insulated when
the cover is open.
Y
N
Replace the L/H Lower Cover Interlock Switch
Replace the MCU PWB
Replace the MCU PWB
(PL
9.1).
February, 2008
2-555
(PL
2.5).
(PL
2.5) correctly.
P/J106
and P/J410.
P/J106
and
P/J410
(PL
2). The wire between J410-11 and J410-12 is con-
(PL
2.5).
(PL
9.1).
077-308, 077-309
are connected cor-
Flag
2.5) between J410-11
Status Indicator Raps

Advertisement

Table of Contents
loading

This manual is also suitable for:

Workcentre 5225Workcentre 5230

Table of Contents