6 Calibration
6.3.1 Updating revolution counters on OmniCore robots
Continued
Correct synchronization position of axes 3 and 4
When jogging the manipulator to synchronization position, it is extremely important
to make sure that axes 3 and 4 are positioned correctly.
IP30
xx1900000147
Continues on next page
794
Note
At delivery the manipulator is in the correct position. Do NOT shift axis 3 or rotate
axis 4 at power up before the revolution counters are updated.
If axis 4 is rotated one or more turns from its calibration position before updating
the revolution counter, the correct calibration position will be lost due to
non-integer gear ratio. This will further affect the calibration position of axis 3.
© Copyright 2019-2022 ABB. All rights reserved.
3
4
Product manual - IRB 910INV
3HAC068055-001 Revision: K