ABB IRB 910INV Product Manual page 423

Hide thumbs Also See for IRB 910INV:
Table of Contents

Advertisement

3
4
Concluding procedure
1
Product manual - IRB 910INV
3HAC068055-001 Revision: K
Action
For robots with protection class IP54 (option 3350-
540)
For robots with protection type Clean Room (op-
tion 3351-1)
Pull the upper end of the bellow to the outer arm.
Tip
For robots with protection class IP54 (option 3350-
540)
Hold the bellow for a little while until it's attached
to the housing.
For robots with protection class IP54 (option 3350-
540)
For robots with protection type Clean Room (op-
tion 3351-1)
Secure them with the clamp.
Tip
The opening part of the clamp should be in the
opposite position to the gap on the bellow gasket.
Action
For robots with protection type Clean Room:
Seal and paint the joints that have been opened.
See
Cut the paint or surface on the robot before
replacing parts on page 118
Note
After all repair work, wipe the Clean Room robot
free from particles with spirit on a lint free cloth.
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.6.2 Replacing the bellows
Continued
Note
xx1900001613
Tightening torque: 0.6 Nm ±10%
xx1900001611
xx1900001625
Note
Continues on next page
423

Advertisement