3
4
5
6
Product manual - IRB 910INV
3HAC068055-001 Revision: K
Action
For robots with protection class IP54 (option 3350-
540)
Apply the glue to the corner of the upper housing.
For robots with protection class IP54 (option 3350-
540)
For robots with protection type Clean Room (op-
tion 3351-1)
Install the bellow to the upper housing.
Tip
For robots with protection class IP54 (option 3350-
540)
Hold the bellow for a little while until it's attached
to the housing.
For robots with protection class IP54 (option 3350-
540)
Install the bellow gaskets to the bellow
Tip
The angle between the gap on the bellow gasket
and gap on the inner bellow gasket should be 90
degrees.
For robots with protection class IP54 (option 3350-
540)
For robots with protection type Clean Room (op-
tion 3351-1)
Secure the bellow and the gasket with the clamp.
Tip
The opening part of the clamp should be in the
opposite position to the gap on the bellow gasket.
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.6.2 Replacing the bellows
Continued
Note
xx1900001559
xx1900001560
xx1900001561
Tightening torque: 0.6 Nm ±10%
xx1900001563
Continues on next page