5 Repair
5.3.3 Replacing the process hub
Continued
Spare part
Gasket, Process Hub
Required tools and equipment
Equipment
Standard toolkit
Calibration tool box, Axis Calibra-
tion
i
Required consumables
Consumable
Cable straps
Grease
Deciding calibration routine
Decide which calibration routine to be used, based on the information in the table.
Depending on which routine is chosen, action might be required prior to beginning
the repair work of the robot, see the table.
1
Continues on next page
190
The robot is calibrated by either manual calibration or Axis Calibration at ABB factory before delivery.
Always use the same calibration method as used at the factory.
Information about valid calibration method is found on the calibration label or in the calibration
menu on the FlexPendant.
If no data is found related to standard calibration, manual calibration is used as default.
Action
Decide which calibration routine to use for
calibrating the robot.
Reference calibration. External cable
packages (DressPack) and tools can
stay fitted on the robot.
Fine calibration. All external cable
packages (DressPack) and tools
must be removed from the robot.
If the robot is to be calibrated with refer-
ence calibration:
Find previous reference values for the axis
or create new reference values. These val-
ues are to be used after the repair proced-
ure is completed, for calibration of the ro-
bot.
If no previous reference values exist, and
no new reference values can be created,
then reference calibration is not possible.
© Copyright 2019-2022 ABB. All rights reserved.
Article number
Note
3HAC061872-001
Replace if damaged.
Article number
Note
-
Content is defined in section
Standard toolkit on page
3HAC074119-001
Delivered as a set of calibration
tools.
Required if Axis Calibration is the
valid calibration method for the
robot.
Article number
Note
-
3HAC029132-001
FM 222
Used to lubricate the cable har-
ness.
Note
Follow the instructions given in the refer-
ence calibration routine on the FlexPendant
to create reference values.
Creating new values requires possibility to
move the robot.
Read more about reference calibration for
Axis Calibration in
routine on page
Product manual - IRB 910INV
840.
i
Reference calibration
798.
3HAC068055-001 Revision: K