5 Repair
5.6.5 Replacing the ball screw
Continued
Refitting the extension shaft for Clean Room/ IP54 robots
1
2
3
Continues on next page
486
Action
For robots with protection type Clean Room:
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free. See
Cut the paint or surface on the robot
before replacing parts on page 118
Note
After all repair work, wipe the Clean Room robot
free from particles with spirit on a lint free cloth.
For robots with protection class IP54 (option 3350-
540)
For robots with protection type Clean Room (op-
tion 3351-1)
Install the extension shaft to the ball screw on the
upper side of the mechanical stopper.
For robots with protection class IP54 (option 3350-
540)
For robots with protection type Clean Room (op-
tion 3351-1)
Secure the extension shaft to the mechanical
stopper with the screws.
© Copyright 2019-2022 ABB. All rights reserved.
Note
xx1900001558
For IRB 910INV-3/0.35:
Screws: Hex socket head cap
screw M3x20 12.9 Lafre
2C2B/FC6.9 (2 pcs)
Tightening torque: 1.2 Nm ±10%
For IRB 910INV-6/0.55:
Screws: Hex socket head cap
screw M3x20 12.9 Lafre
2C2B/FC6.9 (2 pcs)
Tightening torque: 1.2 Nm ±10%
xx1900001557