ABB IRB 910INV Product Manual page 321

Hide thumbs Also See for IRB 910INV:
Table of Contents

Advertisement

2
3
Refitting the cable bracket
1
Product manual - IRB 910INV
3HAC068055-001 Revision: K
Action
Refit the cable ferrule to the bracket and secure
with the screws.
Refit the bracket into the inner arm and secure
with the screws.
Action
For robots with protection type Clean Room:
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free. See
Cut the paint or surface on the robot
before replacing parts on page 118
Note
After all repair work, wipe the Clean Room robot
free from particles with spirit on a lint free cloth.
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.5.1 Replacing the inner arm
Continued
Note
Screws: Hex socket head cap
screw M3x5 12.9 Lafre 2C2B/FC6.9
(2 pcs)
Tightening torque: 1.5 Nm ±10%
xx1800003409
Screws: Hex socket head cap
screw M3x5 12.9 Lafre 2C2B/FC6.9
(2 pcs)
Tightening torque: 1.5 Nm ±10%
xx1800003408
Note
Continues on next page