3
4
5
Product manual - IRB 910INV
3HAC068055-001 Revision: K
Action
Disconnect the air hoses from the L-shaped con-
nectors.
For robots with C1 cabling
Disconnect the connector.
R2.C1
For robots with C2 cabling
Disconnect the connector.
R1.C2
Tip
Cut the cable straps for the R1.C2 at the same
time.
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
Tip
The connector clip has to be pressed (1) and
pushed forward (2) to separate the R1.C2 (for C2
cabling).
xx1800002943
© Copyright 2019-2022 ABB. All rights reserved.
5.3.2 Replacing the internal harness
Note
xx1800002837
xx1900000070
Continues on next page