After calibration
1
Product manual - IRB 910INV
3HAC068055-001 Revision: K
Action
Check that the synchronization marks on axes 3
and 4 are aligned with each other.
Are they aligned within the tolerances?
If yes, the calibration is verified OK.
If no, redo the fine calibration procedure.
Update the revolution counters of axes 3 and 4.
Action
Write down the new system parameters on a new
label and stick on top of the calibration label on
the robot.
© Copyright 2019-2022 ABB. All rights reserved.
6 Calibration
6.5.3 Calibrating axis 3 and axis 4
Note
IP30
xx1900000147
Clean Room/ IP54
F
a
4
a
xx1900001711
a
The three
points need to
be aligned.
b
Axis 2 rotate -
30° for IRB
910INV-3/0.35
Axis 2 rotate -
25° for IRB
910INV-6/0.55
See
Updating revolution counters
on page
780.
Note
Continues on next page
Continued
3
4
F
3
b
F-F