After calibration
1
Product manual - IRB 910INV
3HAC068055-001 Revision: K
Action
Check that the synchronization marks on axes 3
and 4 are aligned with each other.
Are they aligned within the tolerances?
•
If yes, the calibration is verified OK.
•
If no, redo the fine calibration procedure.
Update the revolution counters of axes 3 and 4.
Action
Write down the new system parameters on a new
label and stick on top of the calibration label on
the robot.