ABB IRB 910INV Product Manual page 504

Hide thumbs Also See for IRB 910INV:
Table of Contents

Advertisement

5 Repair
5.6.6 Replacing the axis-3 timing belt
Continued
Equipment
Sonic tension meter
i
Required consumables
Consumable
Cable straps
Deciding calibration routine
Decide which calibration routine to be used, based on the information in the table.
Depending on which routine is chosen, action might be required prior to beginning
the repair work of the robot, see the table.
1
Removing the axis-3 timing belt
Use these procedures to remove the axis-3 timing belt.
Preparations before removing the axis-3 timing belt
1
Continues on next page
504
The robot is calibrated by either manual calibration or Axis Calibration at ABB factory before delivery.
Always use the same calibration method as used at the factory.
Information about valid calibration method is found on the calibration label or in the calibration
menu on the FlexPendant.
If no data is found related to standard calibration, manual calibration is used as default.
Action
Decide which calibration routine to use for
calibrating the robot.
Reference calibration. External cable
packages (DressPack) and tools can
stay fitted on the robot.
Fine calibration. All external cable
packages (DressPack) and tools
must be removed from the robot.
If the robot is to be calibrated with refer-
ence calibration:
Find previous reference values for the axis
or create new reference values. These val-
ues are to be used after the repair proced-
ure is completed, for calibration of the ro-
bot.
If no previous reference values exist, and
no new reference values can be created,
then reference calibration is not possible.
If the robot is to be calibrated with fine
calibration:
Remove all external cable packages
(DressPack) and tools from the robot.
Action
Decide which calibration routine to use, and take
actions accordingly prior to beginning the repair
procedure.
© Copyright 2019-2022 ABB. All rights reserved.
Article number
Note
-
Used for measuring the timing
belt tension.
Article number
Note
-
Note
Follow the instructions given in the refer-
ence calibration routine on the FlexPendant
to create reference values.
Creating new values requires possibility to
move the robot.
Read more about reference calibration for
Axis Calibration in
routine on page
Note
Product manual - IRB 910INV
Reference calibration
798.
3HAC068055-001 Revision: K

Advertisement

Table of Contents
loading

Table of Contents