ABB IRB 910INV Product Manual page 813

Hide thumbs Also See for IRB 910INV:
Table of Contents

Advertisement

The axis-4 calibration is done by rotating the ball screw spline unit so that the
opening gap or the ball screw origin point on the lower mechanical stopper is
aligned with the notch on the outer arm cover.
Required consumables
Equipment
Cleaning agent
Calibrating axis 3 and axis 4
Moving the robot to calibration position
1
2
3
4
5
Product manual - IRB 910INV
3HAC068055-001 Revision: K
Action
Jog axis 2 to the specified position:
-30° for IRB 910INV-3/0.35
-25° for IRB 910INV-6/0.55
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot working
area.
Remove the fitted extra equipment on the robot
if it may cause a collision to the arm when push
the ball screw to the calibration position.
Turn on the electric power to the robot.
DANGER
When releasing the holding brakes, the robot axes
may move very quickly and sometimes in unex-
pected ways!
Make sure the payload is disassembled or tooling
is properly supported; otherwise, fast downward
movements of axis 3 may cause severe hits.
© Copyright 2019-2022 ABB. All rights reserved.
6.5.3 Calibrating axis 3 and axis 4
Art. no.
Note
-
Isopropanol
Note
6 Calibration
Continued
Continues on next page
813

Advertisement

Table of Contents
loading