Removing the axis-2 motor sub-assembly
1
Product manual - IRB 910INV
3HAC068055-001 Revision: K
Action
Remove the screws.
Remove the screws on the cable ferrule to release
the cable.
Disconnect the connectors.
•
R2.MP2
•
R2.FB2
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
© Copyright 2019-2022 ABB. All rights reserved.
5.7.2 Replacing the axis-2 motor sub-assembly
Note
xx1800002874
xx1800002876
xx1800002875
Note
5 Repair