11-193 Decurler Exit Sensor Static Jam RAP

The Control Logic detected paper remained on the Decurler Exit Sensor.
Initial Actions
Refer to BSD12.6 for the following procedure.
Ensure that no paper is blocking the Decurler Exit sensor
Ensure that
P/J651
and
P/J654
Decurler Exit Sensor are connected before beginning this RAP.
Procedure
Enter dC330 012-145 Decurler Exit Sensor. Press Start. The display is H.
Y
N
Go to
Flag
9,
Flag
10, and
Flag 11
If the harness is good, replace the Decurler Exit Sensor
ues, replace the Decurler PWB
(PL
+5VDC is measured between P/J654-2 and GND on the Decurler PWB.
Y
N
Replace the Decurler Exit Sensor
(PL
Check the Decurler Exit Sensor for intermittent operation. If the sensor is good, Replace the
Decurler PWB
(PL
18.6).
Reissue
DocuColor 12/DCCS50
on the Decurler Control PWB, and
P/J658
on BSD12.6 and check the harness for a short circuit.
(PL
18.6). If the problem contin-
18.6).
18.6).

11-301 Mailbox Door Interlock Open RAP

Mailbox Door Interlock Open Failure. This status code is declared when the Mailbox Door Inter-
lock Switch is open.
Initial Actions
Refer to BSD12.1 for the following procedure.
Ensure that
P/J1033
on the Finisher PWB, and
on the
Switch are connected before beginning this RAP.
Check the Front Door for proper alignment.
Verify that the Front Door closes properly.
Procedure
Enter dC330 012-301 Mailbox Door Intlk Sw. The state of the Mailbox Door Interlock
Switch is Low and switches to High when the Mailbox Door is opened.
Y
N
With the Front Cover closed, there is +0 VDC between P/J1033-1 on the Finisher
and GND.
Y
N
Go to the
Flag 1
and
wires are good, replace the Mailbox Door Interlock Switch
continues, replace the Finisher PWB
Check the Mailbox Door Interlock Switch for intermittent operation. Ensure that the switch
and the cover are properly aligned and adjusted. If the problem continues, replace the
Finisher PWB
(PL
18.4).
Check the Mailbox Door Interlock Switch for intermittent operation. Ensure that the switch and
the cover are properly aligned and adjusted. If the problem continues, replace the Finisher
PWB
(PL
18.4).
1/05
11-193 Decurler Exit Sensor Static Jam RAP, 11-
8d-23
P/J1018
on the Mailbox Door Interlock
Flag 2
on BSD12.1. Check the wires for an open circuit. If the
(PL
(PL
18.4).
18.11). If the problem