Cisco MGX 8850 Command Reference Manual page 81

Routing switch
Hide thumbs Also See for Cisco MGX 8850:
Table of Contents

Advertisement

Chapter 2
Shelf Management Commands
Attributes
Log: log
Examples
Configure the E1 clock at the upper connector of the PXM-UI S3 as the primary source. Configure
subport (logical port) 10 on the line of the AXSM-1-2488 in slot 3 as the secondary. For the secondary
source on the AXSM, note the locations of the periods and colons. Upon successful execution, the
system displays a confirmation message.
pinnacle.7.PXM.a> cnfclksrc primary 7.35 -bits e1
Clock Manager has been successfully executed.
pinnacle.7.PXM.a> cnfclksrc secondary 3:1.1:10
Clock Manager has been successfully executed.
Configure a primary network clock to revert to the highest priority E1 clock source after recuperation
from a failure. Upon successful execution, the system displays a confirmation message.
pinnacle.7.PXM.a> cnfclksrc primary 7.36 -bits e1 -revertive enable
Clock Manager has been successfully executed.
Release 2.0, Part Number 78-10467-04 Rev C0, October 2001
State: active
Privilege: GROUP1
Cisco MGX 8850 Routing Switch Command Reference
cnfclksrc
2-23