cnfapsln
Wait To Restore
direction
revertive
Related Commands
addapsln, delapsln, dspapsln, dspapslns, switchapsln, dspapsbkplane, clrbecnt, dspbecnt
Attributes
Log: log
Example
cnfapsln -w 1.1.1 -sf 3 -sd 5 -wtr 5 -dr 2 -rv 1
Cisco MGX 8850 Routing Switch Command Reference
3-24
The number of minutes to wait after the working line has become functional
again, before switching back to the working line from the protection line.
The range is 5–12.
Example: -wtr 5
1: unidirectional, 2: bidirectional
Example: -dr 2
Bidirectional means that both the receiving and transmitting paths are
switched. Unidirectional means that only the affected path, receiving or
transmitting, is switched.
1: non-revertive, 2: revertive
Example: -rv 1