addred

addred
Add Redundancy
Links two slots to support card-level redundancy for a pair of service modules. The pair consists of a
primary slot and a secondary slot. Currently, the only form of redundancy for service modules is 1:1.
Although 1:n appears in the Help display, it is reserved for future use.
To see the slots where redundancy exists, use dspcd or dspcds.
Cards on Which This Command Runs
PXM45
Syntax
addred <redPrimarySlotNum> <redSecondarySlotNum> <RedType>
Syntax Description
redPrimarySlotNum
redSecondarySlotNum
RedType
Related Commands
dspred, delred, switchredcd
Attributes
Log: log
Example
This example adds 1:1 Y Cable redundancy in slots 7 and 8.
MGX8850.7.PXM.a > addred 7.8.1
Cisco MGX 8850 Routing Switch Command Reference
3-18
Slot number that contains the primary card of the pair. The ranges are 1–6
and 9–14 on the
MGX 8850 switch.
Slot number that contains the secondary card. The ranges are 1–6 and 9–14
on the MGX 8850 switch.
Value to set type of redundancy to be deployed on the PXM45.
1 = 1:1 Y Cable
2 = 1:N (reserved for future use)
State: active
Privilege: SUPER_GP
Chapter 3
Equipment and Resource Provisioning
Release 2.0, Part Number 78-10467-04 Rev C0, October 2001