4 cyl. petrol engine (1.8 l and 2.0 l with direct injection, 4 V, exhaust gas turbocharger, timing chain,
– Place end of vent hose -8- of suction-jet pump into a container.
– Connect compressed air hose -6- to suction-jet pump -7-.
– Open shut-off tap -B- on valve block -5-.
The suction-jet pump reduces pressure in the cooling system
to below atmospheric pressure. The pointer of the pressure
gauge must fall to at least -0.85 bar.
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by SEAT S.A. SEAT S.A does not guarantee or accept any liability with
– Close shut-off tap -B-.
respect to the correctness of information in this document. Copyright by SEAT S.A.
– Pull off compressed air hose -6-.
– Observe pressure gauge. The pointer of the pressure gauge
must remain stationary at -0.85 bar at least. The vacuum in
the cooling system is then sufficient for subsequent filling.
Note
If the vacuum drops, the cooling system must be checked for leaks.
The vacuum that builds up depends on the pressure in the compressed air system.