Test Pkt - Avaya Definity SI Maintenance Manual

Table of Contents

Advertisement

test pkt

test pkt
The test pkt runs a series of tests on the Packet bus of the specified PPN or EPN.
Action/Object
Qualifier
test pkt
pn number
port-network
short
long
repeat
number
clear
schedule
1
If no alarms are registered against the maintenance object, then the test sequence is run only once. The long
clear option forces a clear of all alarms if no errors are encountered during testing. The short clear option only
clears alarms pertinent to tests in the short sequence. SEE WARNING BELOW.
2
Refer to the Report Scheduler and System Printer feature specification for more details.
!
WARNING:
Since the clear long options clear all counters if tests pass, it is possible for
firmware counters to be cleared even when a problem exists. In some cases
customer service might degrade since calls may be routed over defective
equipment.
555-233-123
Qualifier Description
The Packet bus to be tested: nn (1-3)
Option for a brief series of
nondestructive diagnostic tests.
Option for a longer, more
comprehensive series of both
destructive and nondestructive
diagnostic tests.
How many times each test in the
sequence is repeated (1-100)
This option causes the test sequence
(short or long) to repeat until the alarm
(if any) is cleared or a single test in the
1
sequence fails.
Command is validated and then a
scheduling form displays to schedule
execution of the command. The
command is then placed in the
command queue and is executed at the
specified time. The information
displayed by the command is sent to
the system printer instead of the
2
screen.
Examples:
test pkt port-network 1 l
test pkt port-network 2 sh r 2
test pkt port-network 2 sh schedule
test pkt port-network 1 l r 25
test pkt port-network 2
test pkt port-network 1 c
Logins
Defaults
init
Test
inads
Sequence =
craft
short;
Repeat = 1
Issue 4 May 2002
Feature
Interactions
none
8-467

Advertisement

Table of Contents
loading

Table of Contents