Avaya S8700 Maintenance Manual page 2176

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
SNI Off-Board Destructive Facility Test (#756)
This test is destructive.
The SNI runs a destructive loop around of the on-board and off-board
Looparound. This test returns the result of the off-board loop around, while
Test #757 returns the result of the on-board loop around.
Table 8-577. TEST #756 SNI Off-Board Destructive Facility Test
Error
Test
Code
Result
Description / Recommendation
1015
ABORT
The system will not allow this test to be run because the SNI circuit pack has
not been busied out. Busyout the SNI circuit pack with busyout board.
Repeat the test board UUCSS long command.
1415
ABORT
The lightwave transceiver is absent.
1. If a lightwave transceiver should not be present, do nothing. For example,
2. Otherwise, check the lightwave transceiver connections.
3. If OK, replace the lightwave transceiver. If a fiber out of frame condition
4. If the test continues to abort, replace the SNI circuit pack.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2300
ABORT
The downlink message necessary to run this test could not be sent.
1. Retry the command at 1-minute intervals up to 3 times.
2301
ABORT
The software timer could not be set before sending the downlink message
necessary to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2304
ABORT
SNI circuit pack responded that it is not able to run the test requested by
software.
1. Retry the command at 1-minute intervals up to 3 times.
8-1454
Issue 1 May 2002
an SNI connected to a DS1C circuit pack or an SNI with a metallic
connection does not have a lightwave transceiver. This test can only be
run when a lightwave transceiver exists.
exists and lightwave transceivers are used, check that the lightwave
transceivers are of the same type, that is, both are 9823a or both are
9823b. If they are not the same type, replace one of the lightwave
transceivers:
9823a is used for distances up to 4900 feet.
9823b is used for distances up to 25,000 feet.
Continued on next page
555-233-143

Advertisement

Table of Contents
loading

Table of Contents