SNI-BD (SNI Circuit Pack)
Table 8-579. TEST #759 Configuration Audit — Continued
Error
Test
Code
Result
Description / Recommendation
120
FAIL
The SNI circuit pack cannot communicate with the equipped SNI in slot 20.
1. Perform the Fiber Fault Isolation Procedure described in Chapter 5. This
2. If the SNI being tested has SNI-PEER error type 3841, replace the SNI
3. If the SNI being tested has SNI-PEER error type 3841, replace the SNI in
133
FAIL
No neighbor link is administered, but the SNI has an EI neighbor.
1. Administer the SNI on a fiber link to the EI neighbor it is connected to via
134
FAIL
No neighbor link is administered, but the SNI has an SNI neighbor.
1. Administer the SNI on a fiber link to the SNI neighbor it is connected to via
135
FAIL
The SNI circuit pack cannot communicate with its neighbor. The SNI has an
administered neighbor, but cannot communicate with its neighbor.
1. Check if the administered neighbor is inserted. If not, insert the neighbor
2. Perform the Fiber Fault Isolation Procedure described in Chapter 5.
136
FAIL
The SNI's administered neighbor does not match the physical neighbor
connected. The type of neighbor administered is an SNI and the type of
neighbor physically connected is an EI. Enter list fiber-link, and verify that the
fiber-optic and metallic cable connections are installed as administered.
137
FAIL
The SNI's administered neighbor does not match the physical neighbor
connected. The type of neighbor administered is an EI and the type of
neighbor physically connected is an SNI. Enter list fiber-link, and verify that
the fiber-optic cable and metallic cable connections are installed as
administered.
555-233-143
will resolve multiple SNI-PEER errors.
being tested. Replacing an SNI may be service interrupting. See
(SNI Circuit Pack)'' on page 8-1429
To view SNI-PEER errors, use the display errors command with category
PNC-PEER. Retry the command.
slot 20. Replacing an SNI may be service interrupting. See
Circuit Pack)'' on page 8-1429
Retry the command.
the add fiber-link next command. Or remove both fiber endpoints (i.e.,
this SNI and its EI neighbor) and remove the fiber endpoints from circuit
pack administration via change circuit-pack.
the add fiber-link next command. Or remove both fiber endpoints (i.e.,
this SNI and its SNI neighbor) and remove the fiber endpoints from circuit
pack administration via change circuit-pack.
circuit pack.
for the procedure for replacing an SNI.
for the procedure for replacing an SNI.