SNI-BD (SNI Circuit Pack)
NOTE:
Test #982 is not an actual demand maintenance test. This test number is
used to report results of executing of the clear firmware-counters
command. Refer to error codes for Test #777.
SNI Circuit Path Test (#755)
This test is nondestructive. This test performs a nondestructive test of the circuit
path.
Table 8-576. TEST #755 SNI Circuit Path Test
Error
Test
Code
Result
Description / Recommendation
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2300
ABORT
The downlink message necessary to run this test could not be sent.
1. Retry the command at 1-minute intervals up to 3 times.
2301
ABORT
The software timer could not be set before sending the downlink message
necessary to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2302
ABORT
Software received incorrect message data from the SNI circuit pack.
1. Retry the command at 1-minute intervals up to 3 times.
2303
ABORT
The SNI circuit pack responded that software test requested is not valid.
1. Retry the command at 1-minute intervals up to 3 times.
2304
ABORT
SNI circuit pack responded that it is not able to run the test requested by
software.
1. Retry the command at 1-minute intervals up to 3 times.
555-233-143