Avaya S8700 Maintenance Manual page 2196

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Table 8-581. TEST #767 Packet Neighbor Link Test — Continued
Error
Test
Code
Result
Description / Recommendation
103
FAIL
The SNI circuit pack cannot communicate with the SNI in slot 3 over the packet
path.
1. Fix any on-board SNI-BD errors against this SNI and the SNI in slot 3. Use
2. Using the display errors command, check the error log for other SNI
3. Replace the SNI being tested.
4. Replace the SNI in slot 3.
104
FAIL
The SNI circuit pack cannot communicate with the SNI in slot 4 over the packet
path.
1. Fix any on-board SNI-BD errors against this SNI and the SNI in slot 4. Use
2. Using the display errors command, check the error log for other SNI
3. Replace the SNI being tested.
4. Replace the SNI in slot 4.
8-1474
Issue 1 May 2002
the display errors command to find any SNI-BD errors and use the display
alarms command to determine whether the errors have on-board alarms.
Then, follow the associated repair procedures for the SNI-BD as described
in the Maintenance manual.
circuit packs with SNI-PEER error type 257. If other SNI circuit packs have
SNI-PEER error type 257 errors, replace the SNI in slot 3. Replacing an
SNI may be service interrupting. See
8-1429
for the procedure for replacing an SNI.
NOTE:
If other SNI circuit packs do not have SNI-PEER error type 257 errors,
the problem could be at either of the peer SNI boards. It is arbitrary as to
which SNI is replaced first.
the display errors command to find any SNI-BD errors and use the display
alarms command to determine whether the errors have on-board alarms.
Then, follow the associated repair procedures for the SNI-BD as described
in the Maintenance manual.
circuit packs with SNI-PEER error type 513. If other SNI circuit packs have
SNI-PEER error type 513 errors, replace the SNI in slot 4. Replacing an
SNI may be service interrupting. See
8-1429
for the procedure for replacing an SNI.
NOTE:
If other SNI circuit packs do not have SNI-PEER error type 513 errors,
the problem could be at either of the peer SNI boards. It is arbitrary as to
which SNI is replaced first.
''SNI-BD (SNI Circuit Pack)'' on page
''SNI-BD (SNI Circuit Pack)'' on page
Continued on next page
555-233-143

Advertisement

Table of Contents
loading

Table of Contents