Avaya S8700 Maintenance Manual page 2164

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
i. This error indicates a processor complex failure.
j. This error indicates that excessive slips have occurred.
k. This error indicates that the SNI cannot communicate with its neighbor.
The SNI is at fault.
l. This error indicates that the SNI cannot communicate with one of its peers.
The SNI is at fault.
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. For example, by clearing error codes associated with the
Configuration audit (#759), you may also clear errors generated from other tests
in the testing sequence.
Order of Investigation
Configuration audit (#759)
Failure audit (#777)
Fiber Out of Frame query (#989)
Packet Neighbor test (#767)
Circuit Path test (#755)
Destructive Facility test (#757)
Off-board Destructive Facility test (#756)
Switch Node Interface Reset test (#761)
1.
D = Destructive, ND = Nondestructive
8-1442
Issue 1 May 2002
3. Replace the fiber link's other endpoint if no DS1C complex is
administered on the fiber link. (Use list fiber-link to
determine whether a DS1C complex is administered). If so,
replace the circuit packs in this order:
. Replace the DS1C circuit pack connected to this SNI.
i
. Replace the other DS1C circuit pack.
ii
. Replace the fiber link's other endpoint.
iii
1. Replace the SNI circuit pack.
Follow the steps for diagnosing synchronization problems when
slips have occurred in the SYNC section.
1. Replace the SNI circuit pack.
1. Replace the SNI circuit pack.
Short Test
Sequence
X
X
X
X
X
Long Test
Reset Board
Sequence
Sequence
X
X
X
X
X
X
X
X
1
D/ND
ND
ND
ND
ND
ND
D
D
D
555-233-143