Table 8-579. TEST #759 Configuration Audit — Continued
Error
Test
Code
Result
Description / Recommendation
114
FAIL
The SNI circuit pack cannot communicate with the equipped SNI in slot 14.
1. Perform the Fiber Fault Isolation Procedure described in Chapter 5. This
2. If the SNI being tested has SNI-PEER error type 2305, replace the SNI
3. If the SNI being tested has SNI-PEER error type 2305, replace the SNI in
115
FAIL
The SNI circuit pack cannot communicate with the equipped SNI in slot 15.
1. Perform the Fiber Fault Isolation Procedure described in Chapter 5. This
2. If the SNI being tested has SNI-PEER error type 2561, replace the SNI
3. If the SNI being tested has SNI-PEER error type 2561, replace the SNI in
116
FAIL
The SNI circuit pack cannot communicate with the equipped SNI in slot 16.
1. Perform the Fiber Fault Isolation Procedure described in Chapter 5. This
2. If the SNI being tested has SNI-PEER error type 2817, replace the SNI
3. If the SNI being tested has SNI-PEER error type 2817, replace the SNI in
555-233-143
will resolve multiple SNI-PEER errors.
being tested. Replacing an SNI may be service interrupting. See
''SNC-BD (Switch Node Clock Circuit Pack)'' on page 8-1384
procedure for replacing an SNI. To view SNI-PEER errors, use the display
errors command with category PNC-PEER. Retry the command.
slot 14. Replacing an SNI may be service interrupting. See
Circuit Pack)'' on page 8-1429
Retry the command.
will resolve multiple SNI-PEER errors.
being tested. Replacing an SNI may be service interrupting. See
(SNI Circuit Pack)'' on page 8-1429
To view SNI-PEER errors, use the display errors command with category
PNC-PEER. Retry the command.
slot 15. Replacing an SNI may be service interrupting. See
Circuit Pack)'' on page 8-1429
Retry the command.
will resolve multiple SNI-PEER errors.
being tested. Replacing an SNI may be service interrupting. See
(SNI Circuit Pack)'' on page 8-1429
To view SNI-PEER errors, use the display errors command with category
PNC-PEER. Retry the command.
slot 16. Replacing an SNI may be service interrupting. See
Circuit Pack)'' on page 8-1429
Retry the command.
for the procedure for replacing an SNI.
for the procedure for replacing an SNI.
for the procedure for replacing an SNI.
for the procedure for replacing an SNI.
for the procedure for replacing an SNI.