2 Parameters
2.2 List of parameters
p2238[0...n]
Technology controller motorized potentiometer minimum value / Tec_ctrl mop min
VECTOR_G
Can be changed: U, T
(Tech_ctrl)
Data type: FloatingPoint32
P-Group: Technology
Not for motor type: -
Min
-200.00 [%]
Description:
Sets the minimum value for the motorized potentiometer of the technology controller.
Dependency:
Refer to: p2237
p2240[0...n]
Technology controller motorized potentiometer starting value / Tec_ctrl mop start
VECTOR_G
Can be changed: U, T
(Tech_ctrl)
Data type: FloatingPoint32
P-Group: Technology
Not for motor type: -
Min
-200.00 [%]
Description:
Sets the starting value for the motorized potentiometer of the technology controller.
For p2230.0 = 0, this setpoint is entered after ON.
Dependency:
Refer to: p2230
r2245

CO: Technology controller mot. potentiometer setpoint before RFG /

Tec_ctr mop befRFG
VECTOR_G
Can be changed: -
(Tech_ctrl)
Data type: FloatingPoint32
P-Group: Technology
Not for motor type: -
Min
- [%]
Description:
Sets the effective setpoint in front of the internal motorized potentiometer ramp-function generator of the technology
controller.
Dependency:
Refer to: r2250
p2247[0...n]
Technology controller motorized potentiometer ramp-up time / Tec_ctr mop t_r-up
VECTOR_G
Can be changed: U, T
(Tech_ctrl)
Data type: FloatingPoint32
P-Group: Technology
Not for motor type: -
Min
0.0 [s]
Description:
Sets the ramp-up time for the internal ramp-function generator for the motorized potentiometer of the technology
controller.
Dependency:
Refer to: p2248
Note:
The time is referred to 100 %.
When the initial rounding-off is activated (p2230.2 = 1) the ramp-up is correspondingly extended.
534
Calculated: -
Dyn. index: DDS, p0180
Units group: 9_1
Scaling: -
Max
200.00 [%]
Calculated: -
Dyn. index: DDS, p0180
Units group: 9_1
Scaling: -
Max
200.00 [%]
Calculated: -
Dyn. index: -
Units group: 9_1
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: DDS, p0180
Units group: -
Scaling: -
Max
1000.0 [s]
List Manual (LH2), 04/2014, A5E03263479A
Access level: 2
Func. diagram: 7954
Unit selection: p0595
Expert list: 1
Factory setting
-100.00 [%]
Access level: 2
Func. diagram: 7954
Unit selection: p0595
Expert list: 1
Factory setting
0.00 [%]
Access level: 2
Func. diagram: 7954
Unit selection: p0595
Expert list: 1
Factory setting
- [%]
Access level: 2
Func. diagram: 7954
Unit selection: -
Expert list: 1
Factory setting
10.0 [s]