Si Diagnostics Component Replacement / Diag Comp_Replace; Si Crosswise Comparison List (Control Unit) / Si Cdc_List Cu; Si Diagnostics Stop F (Control Unit) / Si Diag Stop F Cu; Si Actual Checksum Si Parameters (Control Unit) / Si Act_Checksum Cu - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
r9793[0...9]

SI diagnostics component replacement / Diag comp_replace

VECTOR_G
Can be changed: -
Data type: Unsigned8
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Displays the component number for the first 10 replaced safety-relevant components.
Dependency:
Refer to: r9776
Note:
This parameter does not exist for a Control Unit and Terminal Module.
r9794[0...19]

SI crosswise comparison list (Control Unit) / SI CDC_list CU

VECTOR_G
Can be changed: -
Data type: Unsigned16
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Displays the number of the data that are being presently compared crosswise on the Control Unit.
The content of the list of crosswise-compared data is dependent upon the particular application.
Dependency:
Refer to: r9894
Note:
Example:
r9794[0] = 1 (monitoring clock cycle)
r9794[1] = 2 (enable safety functions)
r9794[2] = 3 (F-DI changeover, tolerance time)
...
A complete list of numbers for crosswise-compared data items appears in fault F01611.
r9795

SI diagnostics STOP F (Control Unit) / SI diag STOP F CU

VECTOR_G
Can be changed: -
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Displays the number of the cross-compared data which has caused STOP F on the Control Unit.
Dependency:
Refer to: r9895
Note:
A complete list of numbers for crosswise-compared data items appears in fault F01611.
r9798

SI actual checksum SI parameters (Control Unit) / SI act_checksum CU

VECTOR_G
Can be changed: -
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Displays the checksum over the checked Safety Integrated parameters on the Control Unit (actual checksum).
Dependency:
Refer to: p9799, r9898
938
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
List Manual (LH2), 04/2014, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: 2802
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 2
Func. diagram: 2802
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: 2800
Unit selection: -
Expert list: 1
Factory setting
-