r7102[0...99]

Par_circuit ring buffer fault/alarm received / F/A received

B_INF (Parallel),
Can be changed: -
VECTOR_G (Parallel)
Data type: Unsigned32
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Ring buffer for faults and alarms that have occurred from power units connected in parallel (Motor Module, Active
Line Infeed, Voltage Sensing Module).
Displays the relative system runtime when the fault or alarm occurred.
Dependency:
Refer to: r7100, r7101, r7103
Note:
The last fault case that occurred is documented in index 0.
The parameter is reset to 0 at POWER ON.
r7103[0...99]

Par_circuit ring buffer fault/alarm gone / F/A gone

B_INF (Parallel),
Can be changed: -
VECTOR_G (Parallel)
Data type: Unsigned32
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Ring buffer for faults and alarms that have occurred from power units connected in parallel (Motor Module, Active
Line Infeed, Voltage Sensing Module).
Displays the relative system runtime when the fault or alarm was withdrawn.
Dependency:
Refer to: r7100, r7101, r7102
Note:
The last fault case that occurred is documented in index 0.
The parameter is reset to 0 at POWER ON.
r7200[0...n]

Par_circuit power unit overload I2t / PU overload I2t

VECTOR_G (Parallel) Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [%]
Description:
Displays the overload of the particular power unit in a parallel circuit configuration calculated using the I2t function.
The maximum value of all power units is displayed in r0036.
r7201[0...n]
CO: Par_circuit power unit temperatures max. inverter / PU temp max inv
B_INF (Parallel),
Can be changed: -
VECTOR_G (Parallel)
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [°C]
Description:
Displays the maximum inverter temperature in the power unit for a parallel circuit configuration.
The maximum value of all power units is displayed in r0037[0].
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: PDS, p0120
Units group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: PDS, p0120
Units group: 21_1
Scaling: p2006
Max
- [°C]
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
- [°C]
707