Bits 20, 19, 18, 17, 16 = 1, 0, 0, 1, 0 --> PROFIdrive message class 18: error in the
parameterization/configuration/commissioning sequence
Bits 20, 19, 18, 17, 16 = 1, 0, 0, 1, 1 --> PROFIdrive message class 19: general drive fault
r3131

CO: Actual fault value / Act fault val

All objects
Can be changed: -
Data type: Integer32
P-Group: Messages
Not for motor type: -
Min
-
Description:
Displays the fault value of the oldest active fault.
Dependency:
Refer to: r2131, r3132
r3132

CO: Actual component number / Comp_no act

All objects
Can be changed: -
Data type: Integer32
P-Group: Messages
Not for motor type: -
Min
-
Description:
Displays the component number of the oldest fault that is still active.
Dependency:
Refer to: r2131, r3131
p3135

Suppress active fault / Supp act flt

B_INF, VECTOR_G
Can be changed: U, T
Data type: Unsigned32
P-Group: Messages
Not for motor type: -
Min
-
Description:
Sets the suppression of r2139.3 "Fault present" for certain fault responses.
Bit field:
Bit
08
10
Dependency:
Refer to: p0491, r2139
Note:
Depending on the suppression of a fault reaction in this parameter, r2139.1 "Acknowledgement required" is set when
at least one fault occurs.
Re bit 08:
The suppression is only effective if p0491 = 1.
p3201[0...n]
Excitation current outside the tolerance threshold value / I_exc n Tol thresh
VECTOR_G
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Messages
Not for motor type: ASM, PEM, REL
Min
0.1 [%]
Description:
Sets the threshold value for the "excitation current outside tolerance" message for the excitation current monitoring.
If the absolute value of the difference between the excitation current setpoint and actual value (r1641 - r1626)
exceeds the threshold value and the hysteresis is longer than the selected delay time, then fault F07913 is output.
This fault is withdrawn when the threshold voltage is undershot.
Dependency:
Refer to: r1626, r1641, p3202, p3203
Note:
The monitoring function is only carried out for separately-excited synchronized motors (p0300 = 5).
560
Signal name
Suppression of fault response ENCODER
Suppression of fault response NONE
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
ON
ON
Calculated: -
Dyn. index: DDS, p0180
Units group: -
Scaling: -
Max
100.0 [%]
List Manual (LH2), 04/2014, A5E03263479A
Access level: 3
Func. diagram: 8060
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: 8060
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 4
Func. diagram: 8060
Unit selection: -
Expert list: 1
Factory setting
0000 0000 0000 0000 bin
0 signal
OFF
OFF
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
10.0 [%]