Motor Damping Inductance Q Axis Scaling / Mot L_Damp Q Scal; Motor Damping Resistance D Axis Scaling / Mot R_Damp D Scal; Motor Damping Resistance Q Axis Scaling / Mot R_Damp Q Scal; Central Measuring Probe Input Terminal / Cen Meas Inp - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
Dependency:
Refer to: p0358, r0380
p0658[0...n]

Motor damping inductance q axis scaling / Mot L_damp q scal

VECTOR_G
Can be changed: C2(3), U, T
Data type: FloatingPoint32
P-Group: Motor
Not for motor type: ASM, PEM, REL
Min
10.0 [%]
Description:
Factor to evaluate the damping inductance quadrature to the rotor axis (q axis).
Dependency:
Refer to: p0359, r0381
p0659[0...n]

Motor damping resistance d axis scaling / Mot R_damp d scal

VECTOR_G
Can be changed: C2(3), U, T
Data type: FloatingPoint32
P-Group: Motor
Not for motor type: ASM, PEM, REL
Min
10.0 [%]
Description:
Factor to evaluate the damping resistance in the direction of the rotor axis (d axis).
Dependency:
Refer to: p0354, r0374
p0660[0...n]

Motor damping resistance q axis scaling / Mot R_damp q scal

VECTOR_G
Can be changed: C2(3), U, T
Data type: FloatingPoint32
P-Group: Motor
Not for motor type: ASM, PEM, REL
Min
10.0 [%]
Description:
Factor to evaluate the damping resistance quadrature to the rotor axis (q axis).
Dependency:
Refer to: p0355, r0375
p0680[0...7]

Central measuring probe input terminal / Cen meas inp

CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: Integer16
CU_G150_DP,
P-Group: Encoder
CU_G150_PN
Not for motor type: -
Min
0
Description:
Sets the digital input used for the function "central measuring probe evaluation".
p0680[0]: Digital input, measuring probe 1
p0680[1]: Digital input, measuring probe 2
...
p0680[7]: Digital input, measuring probe 8
Value:
0:
1:
2:
3:
4:
5:
6:
7:
8:
Dependency:
Refer to: p0728
232
No meas probe
DI/DO 9 (X122.10/X121.8)
DI/DO 10 (X122.12/X121.10)
DI/DO 11 (X122.13/X121.11)
DI/DO 13 (X132.10/X131.2)
DI/DO 14 (X132.12/X131.4)
DI/DO 15 (X132.13/X131.5)
DI/DO 8 (X122.9/X121.7)
DI/DO 12 (X132.9/X131.1)
Calculated: CALC_MOD_EQU
Dyn. index: MDS, p0130
Units group: -
Scaling: -
Max
300.0 [%]
Calculated: CALC_MOD_EQU
Dyn. index: MDS, p0130
Units group: -
Scaling: -
Max
300.0 [%]
Calculated: CALC_MOD_EQU
Dyn. index: MDS, p0130
Units group: -
Scaling: -
Max
300.0 [%]
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
8
List Manual (LH2), 04/2014, A5E03263479A
Access level: 4
Func. diagram: 6727
Unit selection: -
Expert list: 1
Factory setting
100.0 [%]
Access level: 4
Func. diagram: 6727
Unit selection: -
Expert list: 1
Factory setting
100.0 [%]
Access level: 4
Func. diagram: 6727
Unit selection: -
Expert list: 1
Factory setting
100.0 [%]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0