r9207

Topology direct access integer value / Topo access int

CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: Unsigned32
CU_G150_DP,
P-Group: Topology
CU_G150_PN
Not for motor type: -
Min
-
Description:
Displays the value for the property set in p9206.
A value is only displayed for integer type properties.
Dependency:
Refer to: p9206, r9208
r9208[0...50]

Topology direct access string / Topo access string

CU_G130_DP,
Can be changed: -
CU_G130_PN,
Data type: Unsigned8
CU_G150_DP,
P-Group: Topology
CU_G150_PN
Not for motor type: -
Min
-
Description:
Displays the value for the property set in p9206.
A value is only displayed for string type properties.
Dependency:
Refer to: p9206, r9207
Note:
An ASCII table (excerpt) can be found, for example, in the appendix to the List Manual.
p9210

Flashing component number / Flash comp_no

CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: Unsigned16
CU_G150_DP,
P-Group: Topology
CU_G150_PN
Not for motor type: -
Min
0
Description:
Sets the component number for a component to get its status LED to flash.
Dependency:
Refer to: p9211
p9211

Flash function / Flash fct.

CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: Integer16
CU_G150_DP,
P-Group: Topology
CU_G150_PN
Not for motor type: -
Min
-1
Description:
Sets the function for the component selected in p9210.
After initiating a function, the parameter is automatically reset again.
Example:
- Set the component number (p9210).
- Select the "flashing on" function (set p9211 = 1).
Value:
-1:
0:
1:
Dependency:
Refer to: p9210
Notice:
If a task cannot be executed (e.g. the component number in p9210 does not exist), the following applies:
- There is no negative feedback signal.
- The value is reset anyway.
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Select function
Flashing off
Flashing on
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
499
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
1
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-1