r6991[0...4]
Recorder settings display / Rec setting displ
B_INF (Recorder),
Can be changed: -
VECTOR_G
Data type: FloatingPoint32
(Recorder)
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the values calculated for the recorder
Index:
[0] = Actual trace number
[1] = Actual trace duration
[2] = Actual pretrigger time
[3] = Actual post trigger time
[4] = Actual number of signals
Dependency:
Refer to: p6999
r6992.0...14
CO/BO: Recorder status word / Rec ZSW
B_INF (Recorder),
Can be changed: -
VECTOR_G
Data type: Unsigned16
(Recorder)
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Displays the status word of the recorder.
Bit field:
Bit
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
Dependency:
Refer to: p6993, p6994, r6997, p6998, p6999
p6993[0...2]
Recorder trigger 2 bit mask / Rec trig 2 mask
B_INF (Recorder),
Can be changed: U, T
VECTOR_G
Data type: Unsigned32
(Recorder)
P-Group: -
Not for motor type: -
Min
0000 hex
Description:
Sets the bit mask for trigger signal 2 (p6994) of the recorder.
Trigger 2.1 is formed by ANDing the signal source in p6994[0] and the bit mask in p6993[0].
Trigger 2.2 is formed by ANDing the signal source in p6994[1] and the bit mask in p6993[1].
Trigger 2.3 is formed by ANDing the signal source in p6994[2] and the bit mask in p6993[2].
Index:
[0] = Trigger 2.1
[1] = Trigger 2.2
[2] = Trigger 2.3
Dependency:
Refer to: p6994
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Signal name
Internal activation
External activation
Internal trigger
External trigger 1.1
External trigger 1.2
External trigger 1.3
External trigger 1.4
External trigger 2.1
External trigger 2.2
External trigger 2.3
Hardware trigger
Data buffering running
Post trigger time running
Data being stored
Data buffer full
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
1 signal
Set
Set
Set
Set
Set
Set
Set
Set
Set
Set
Set
Yes
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
FFFF FFFF hex
2 Parameters
2.2 List of parameters
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 4
Func. diagram: 8144
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
Not set
Not set
Not set
Not set
Not set
Not set
Not set
Not set
Not set
Not set
Not set
No
No
No
No
Access level: 4
Func. diagram: 8144
Unit selection: -
Expert list: 1
Factory setting
0001 hex
FP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
697