2 Parameters
2.2 List of parameters
p9915
DRIVE-CLiQ data transfer error shutdown threshold master / DQ fault master
CU_G130_DP,
Can be changed: C1(1)
CU_G130_PN,
Data type: Unsigned32
CU_G150_DP,
P-Group: Topology
CU_G150_PN
Not for motor type: -
Min
0000 hex
Description:
Only for internal Siemens service purposes.
p9916
DRIVE-CLiQ data transfer error shutdown threshold slave / DQ fault slave
CU_G130_DP,
Can be changed: C1(1)
CU_G130_PN,
Data type: Unsigned32
CU_G150_DP,
P-Group: Topology
CU_G150_PN
Not for motor type: -
Min
0000 hex
Description:
Only for internal Siemens service purposes.
p9917[0...1]

Delete component / Delete comp

CU_G130_DP,
Can be changed: C1(30)
CU_G130_PN,
Data type: Unsigned16
CU_G150_DP,
P-Group: -
CU_G150_PN
Not for motor type: -
Min
0
Description:
Excessive components that have not been assigned can be removed from the component target topology using this
parameter.
Index 0:
The values 2 ... 199 are permissible.
Index 1:
= 0: Ready.
= 1: Reset (only indices 0 and 1)
= 2: Reset all (indices 0 and 1 and flagged entries).
= 3: Check and flag for deletion.
Index:
[0] = Component number
[1] = Reset or check and flag for deletion
Note:
Only for internal Siemens use.
The parameter is not displayed for the STARTER commissioning software.
p9920[0...99]

Licensing enter license key / Enter license key

CU_G130_DP,
Can be changed: U, T
CU_G130_PN,
Data type: Unsigned8
CU_G150_DP,
P-Group: -
CU_G150_PN
Not for motor type: -
Min
-
Description:
Enters the license key for this drive unit.
Example of the license key:
EACZ-QBCA = 69 65 67 90 45 81 66 67 65 dec (ASCII characters)
Index 0 = license key character 1 (e.g. 69 dec)
Index 1 = license key character 2 (e.g. 65 dec)
...
954
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
0007 07FF hex
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
0007 07FF hex
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
199
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
List Manual (LH2), 04/2014, A5E03263479A
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0007 02FF hex
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0007 02FF hex
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-