2 Parameters
2.2 List of parameters
r1641

Excitation current actual value / I_exc_act val

VECTOR_G (n/M)
Can be changed: -
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: ASM, PEM, REL
Min
- [%]
Description:
Displays the excitation current actual value that is read in.
Dependency:
Refer to: p0390
p1642[0...n]

Minimum excitation current / Min I_exc

VECTOR_G (n/M)
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: ASM, PEM, REL
Min
0.1 [%]
Description:
Sets the minimum excitation current.
This means that negative excitation currents can be avoided.
p1643[0...n]
Minimum excitation current closed-loop control gain factor / I_exc_min Kp
VECTOR_G (n/M)
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: ASM, PEM, REL
Min
0.00
Description:
Sets the gain factor for the minimum excitation current, closed-loop control.
This is active if the excitation current is below 75 % of p1642.
Dependency:
Refer to: p1642
r1644

CO: Excitation current monitoring output / I_exc_monit outp

VECTOR_G (n/M)
Can be changed: -
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: ASM, PEM, REL
Min
- [Arms]
Description:
Displays the output of the excitation current monitoring for separately excited synchronous motors.
p1645[0...7]
BI: Excitation feedback signals signal source / Exc FS S_src
VECTOR_G (n/M)
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: Commands
Not for motor type: ASM, PEM, REL
Min
-
Description:
Sets the signal source for the individual feedback signals from the excitation.
404
Calculated: -
Dyn. index: -
Units group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dyn. index: DDS, p0180
Units group: -
Scaling: -
Max
50.0 [%]
Calculated: CALC_MOD_CON
Dyn. index: DDS, p0180
Units group: -
Scaling: -
Max
5.00
Calculated: -
Dyn. index: -
Units group: 6_2
Scaling: p2002
Max
- [Arms]
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
List Manual (LH2), 04/2014, A5E03263479A
Access level: 3
Func. diagram: 6727, 8018
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 4
Func. diagram: 6727
Unit selection: -
Expert list: 1
Factory setting
5.0 [%]
Access level: 4
Func. diagram: 6727
Unit selection: -
Expert list: 1
Factory setting
0.40
Access level: 4
Func. diagram: 6727
Unit selection: p0505
Expert list: 1
Factory setting
- [Arms]
Access level: 3
Func. diagram: 6495
Unit selection: -
Expert list: 1
Factory setting
[0...6] 1
[7] 0