r9491[0...9]

BI/CI of BICO interconnections to other drives / BI/CI to drive

All objects
Can be changed: -
Data type: Unsigned32
P-Group: Commands
Not for motor type: -
Min
-
Description:
Displays the signal receiver list (Binector Input/Connector Input, BI/CI) for the first interconnections between this
drive and other drives/drive objects.
Dependency:
Refer to: r9490, r9492, p9493
Notice:
A drive cannot be deleted if this list is not empty!
Otherwise, another drive would continue to attempt to read a signal from a drive that no longer existed.
Note:
All indices of r9491 to p9493 designate the same interconnection.
r9491[x] contains the signal receiver and r9492[x] the matching signal source; p9493[x] can be set to modify the
interconnection.
r9492[0...9]

BO/CO of BICO interconnections to other drives / BO/CO to drive

All objects
Can be changed: -
Data type: Unsigned32
P-Group: Commands
Not for motor type: -
Min
-
Description:
Displays the signal source list (Binector Output/Connector Output, BO/CO) for the first interconnections between this
drive and other drives/drive objects.
Dependency:
Refer to: r9490, r9491, p9493
Notice:
A drive cannot be deleted if this list is not empty!
Otherwise, another drive would continue to attempt to read a signal from a drive that no longer existed.
Note:
All indices of r9491 to p9493 designate the same interconnection.
r9491[x] contains the signal receiver and r9492[x] the matching signal source; p9493[x] can be set to modify the
interconnection.
p9493[0...9]

Reset BICO interconnections to other drives / Reset BICO to drv

All objects
Can be changed: T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Setting to reset the BICO interconnections to other drives.
Each interconnection can be individually reset.
Value:
0:
1:
2:
15:
Dependency:
Refer to: r9490, r9491, r9492
Note:
All indices of r9491 to p9493 designate the same interconnection.
r9491[x] contains the signal receiver and r9492[x] the matching signal source; p9493[x] can be set to modify the
interconnection.
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Set connection to 0
Set connection to 1 (100 %)
Set connection to factory setting
Finished
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
15
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
15
867