2.2 List of parameters
p9495

BICO behavior for de-activated drive objects / Behav for deact DO

B_INF, CU_G130_DP,
Can be changed: T
CU_G130_PN,
Data type: Integer16
CU_G150_DP,
P-Group: -
CU_G150_PN, ENC,
Not for motor type: -
TB30, TM150, TM31,
VECTOR_G
Min
0
Description:
Sets the behavior for BICO interconnections to drive objects that are either not capable of operation or have been
deactivated.
BO/CO parameters are on the drive object that is either not capable of operation or has been deactivated (signal
source).
Value:
0:
1:
2:
Dependency:
Refer to: p9496, p9497, p9498, p9499
Note:
For p9495 = 0, the following applies:
- the number of interconnections is zero (p9497 = 0).
For p9495 not equal to 0, the following applies:
- the BI/CI parameters involved are listed in p9498[0...29] (signal sink).
- the associated BO/CO parameters are listed in p9499[0...29] (signal source).
p9496

BICO behavior when activating drive objects / Behav when act DO

B_INF, CU_G130_DP,
Can be changed: T
CU_G130_PN,
Data type: Integer16
CU_G150_DP,
P-Group: -
CU_G150_PN, ENC,
Not for motor type: -
TB30, TM150, TM31,
VECTOR_G
Min
0
Description:
Sets the behavior when activating BICO interconnections to drive objects that are either not capable of operation or
have been deactivated.
Value:
0:
1:
2:
Dependency:
Refer to: p9495, p9497, p9498, p9499
Note:
The BI/CI parameters involved are listed in p9498[0...29] (signal sink).
The associated BO/CO parameters are listed in p9499[0...29] (signal source).
After p9496 = 1, 2 the following applies:
- p9497 = 0
- p9496 = 0
p9497
BICO interconnections to de-activated drive objects number / Interconn obj qty
B_INF, CU_G130_DP,
Can be changed: T
CU_G130_PN,
Data type: Unsigned16
CU_G150_DP,
P-Group: Commands
CU_G150_PN, ENC,
Not for motor type: -
TB30, TM150, TM31,
VECTOR_G
Min
0
Description:
Displays the number of saved BICO interconnections to drive objects that are either not capable of operation or have
been deactivated.
BO/CO parameters are on the drive object that is either not capable of operation or has been deactivated (signal
source).
Dependency:
Refer to: p9495, p9496, p9498, p9499
868
Inactive
Save interconnections
Save interconnections and establish the factory setting
Inactive
Restore the interconnections from the list
Delete the interconnections from the list
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
2
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
2
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
65535
List Manual (LH2), 04/2014, A5E03263479A
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0